Standard Ranges
|
FP4000-1.0 | −1000 to +1000 µε FP4000-2.5 | −2500 to +2500 µε FP4000-5.0 | −5000 to +5000 µε |
Resolution | FP4000-1.0 | 0.15 µε FP4000-2.5 | 0.30 µε FP4000-5.0 | 0.50 µε |
Gage Factor Accuracy¹
|
FP4000-1.0 | ±3% F.S. FP4000-2.5 | ±3% F.S. FP4000-5.0 | ±10% F.S. |
Temperature Sensitivity
|
0.85 to 1.22 µε/°C
|
Strain Sensitivity | transverse strain insensitive |
Operating Range
|
−40°C to +80°C |
L × W × H | 100 × 25 × 1 mm |
¹The accuracy of the OSP sensors is determined by sample testing of controlled batches at the factory. The manufacturing technique results in the spans shown above and is confirmed by actual strain tests performed on samples from batch lots.