Cảm biến đo ứng suất (Pressure Cells)
Cảm biến đo ứng suất đáy móng Geokon 4810
Giá mời liên hệ
Contact Type (VW) | Model 4810
The Model 4810 “Fat Back” Pressure Cell* is intended to measure contact earth pressures on the surface of concrete or steel structures. The cell has an extra thick backplate to minimize any point loading effects. ‘Ears’ on the cell assist in holding the cell to concrete forms or to retaining walls during installation.
Standard Ranges¹
|
350, 700 kPa; 1, 2, 3, 5 MPa
|
Over Range
|
150% F.S. (maximum)
|
Resolution
|
0.025% F.S.
|
Accuracy²
|
±0.1% F.S.
|
Temperature Range¹
|
−20°C to +80°C
|
Height × Diameter¹
|
12 × 230 mm
|
¹Other ranges and sizes available on request.
²Transducer accuracy established under laboratory conditions.
Total system accuracy (pressure transducer + pressure cell) is subject to site-specific variables.
*Please Note: Models are also available (3500 Series) with semiconductor pressure transducers to enable measurement of dynamic pressures (please contact GEOKON, INCORPORATED for details).
Contact Type (VW) | Model 4810
The Model 4810 “Fat Back” Pressure Cell* is intended to measure contact earth pressures on the surface of concrete or steel structures. The cell has an extra thick backplate to minimize any point loading effects. ‘Ears’ on the cell assist in holding the cell to concrete forms or to retaining walls during installation.
Standard Ranges¹
|
350, 700 kPa; 1, 2, 3, 5 MPa
|
Over Range
|
150% F.S. (maximum)
|
Resolution
|
0.025% F.S.
|
Accuracy²
|
±0.1% F.S.
|
Temperature Range¹
|
−20°C to +80°C
|
Height × Diameter¹
|
12 × 230 mm
|
¹Other ranges and sizes available on request.
²Transducer accuracy established under laboratory conditions.
Total system accuracy (pressure transducer + pressure cell) is subject to site-specific variables.
*Please Note: Models are also available (3500 Series) with semiconductor pressure transducers to enable measurement of dynamic pressures (please contact GEOKON, INCORPORATED for details).