Standard Ranges
|
−100 to 70, 170, 350, 700 kPa; 1, 2, 3, 5, 7.5 MPa
|
Over Range
|
1.5 × rated pressure
|
Resolution
|
0.025% F.S. (minimum)
|
Accuracy
|
±0.1% F.S.
|
Linearity |
<0.5% F.S. (±0.1% F.S. optional)
|
Temperature Range
|
−20°C to +80°C
|
Length × Diameter
|
100 to 150 mm
|
*Please Note: All GEOKON vibrating wire piezometers include tripolar plasma surge arrestors to protect the sensor coils from possible lightning damage. Semiconductor piezometers are also available (see 3400 Series).